6.1 Finished End Panels / Appliance Panels

Compliance Standards
AWI PremiumPending review
AWI CustomPending review
AWI EconomyPending review
ADA StandardsN/A
Notes / Requirements
  • Finished end panels are ¾″ standard.
  • Undercounter panels ship 1″ taller than the countertop mounting height. The extra 1″ is scribe allowance and is trimmed in the field.
  • Undercounter panel depth is 1″ less than the countertop depth, so the countertop runs past the panel.
  • Full-height panels (refrigerator and appliance style) run ⅛″ minimum to ¼″ maximum past the countertop depth. The panel caps the countertop end.
  • The two conditions run opposite directions at the front edge. Undercounter panels sit back from the countertop; full-height panels project past it. Confirm which condition applies before cutting.

Conditions:

ConditionHeightDepth
Undercounter finished endCountertop mounting ht. + 1″ (field trim)Countertop depth − 1″
Full-height / appliance panelPer elevationCountertop depth + ⅛″ min. to ¼″ max.

Drawings:

FINISHED END PANEL COUNTERTOP (BEYOND) FIELD TRIM COUNTERTOP MTG. HT. WALL FLOOR 1″ 1″ UNDERCOUNTER FINISHED END (SECTION)